EMPR

GMP Series

Multi-Protection Wide and adjustable current setting range Adjustable trip time (trip class 5-10-15-20-30) Various connection way Screw connection & Separate mount, Direct mount, Passing through CT holes & Separate mountable on 35mm DIN rail or with screws 1C, 1NO+1NC trip contacts Manual reset as standard (Automatic reset optional) Indicate the cause of the fault by the LEDs

  • 22A Inverse time characteristics
    Description
    • Wide and adjustable current range
    • Adjustable trip time (trip class 5-10-15-20-30)
    • Designed suitable for use with contactors
      Directly mountable on the GM-9, 12, 18, 22 contactors
      Separate mount versions are also available
      Separately mountable on 35mm DIN rail or with screws
    • 1NO+1NC trip contacts
    • Manual reset as standard (Automatic reset optional)
    Extended protective functions
    Extended protective functions
    Number of sensors 2CT 3CT 3CT
    Types (GMP22-) (-2P, -2T, -2S) (-3P, -3T, -3S) (-3PR, -3TR, -3SR)
    Functions Overcurrent
    Phase loss
    Locked rotor
    Phase unbalance ·
    Phase reversed · ·
    40A Inverse time characteristics
    Description
    • Wide and adjustable current range
    • Adjustable trip time (trip class 5-10-15-20-30)
    • Designed suitable for use with contactors
      Directly mountable on the GM-32, 40 contactors
      Separate mount versions are also available
      Separately mountable on 35mm DIN rail or with screws
    • 1NO+1NC trip contacts
    • Manual reset as standard (Automatic reset optional)
    Extended protective functions
    Extended protective functions
    Number of sensors 2CT 3CT 3CT
    Types (GMP40-) (-2P, -2T, -2S) (-3P, -3T, -3S) (-3PR, -3TR, -3SR)
    Functions Overcurrent
    Phase loss
    Locked rotor
    Phase unbalance ·
    Phase reversed · ·
    60A Definite time characteristics
    Description
    • Small size, economical
    • Delay time setting in starting and operation
    • Over current, phase failure protection
    • Definite time characteristics
    • Wide current setting range
    • Screw or Din-rail mounting
    Extended protective functions
    Extended protective functions
    Number of sensors 2CT
    Types (GMP-60T) Tunnel Type
    Functions Overcurrent
    Phase loss ■ Note1)
    Locked rotor
    Phase unbalance ·
    Phase reversed ·
Ratings
Model GMP22 -2P GMP22 -2P(1a1b) GMP22 -3P/3PR GMP22 -2S GMP22 -3S/3SR GMP22 -2T GMP22 -3T/3TR
Ratings
Type Pin type Screw type Tunnel type
No. of CT 2CT 2CT 3CT 2CT 3CT 2CT 3CT
Protection Overcurrent
Phase failure  Note1)
+ Product

EMPR

GMP Series

Multi-Protection Wide and adjustable current setting range Adjustable trip time (trip class 5-10-15-20-30) Various connection way Screw connection & Separate mount, Direct mount, Passing through CT holes & Separate mountable on 35mm DIN rail or with screws 1C, 1NO+1NC trip contacts Manual reset as standard (Automatic reset optional) Indicate the cause of the fault by the LEDs

+ Features
  • 22A Inverse time characteristics
    Description
    • Wide and adjustable current range
    • Adjustable trip time (trip class 5-10-15-20-30)
    • Designed suitable for use with contactors
      Directly mountable on the GM-9, 12, 18, 22 contactors
      Separate mount versions are also available
      Separately mountable on 35mm DIN rail or with screws
    • 1NO+1NC trip contacts
    • Manual reset as standard (Automatic reset optional)
    Extended protective functions
    Extended protective functions
    Number of sensors 2CT 3CT 3CT
    Types (GMP22-) (-2P, -2T, -2S) (-3P, -3T, -3S) (-3PR, -3TR, -3SR)
    Functions Overcurrent
    Phase loss
    Locked rotor
    Phase unbalance ·
    Phase reversed · ·
    40A Inverse time characteristics
    Description
    • Wide and adjustable current range
    • Adjustable trip time (trip class 5-10-15-20-30)
    • Designed suitable for use with contactors
      Directly mountable on the GM-32, 40 contactors
      Separate mount versions are also available
      Separately mountable on 35mm DIN rail or with screws
    • 1NO+1NC trip contacts
    • Manual reset as standard (Automatic reset optional)
    Extended protective functions
    Extended protective functions
    Number of sensors 2CT 3CT 3CT
    Types (GMP40-) (-2P, -2T, -2S) (-3P, -3T, -3S) (-3PR, -3TR, -3SR)
    Functions Overcurrent
    Phase loss
    Locked rotor
    Phase unbalance ·
    Phase reversed · ·
    60A Definite time characteristics
    Description
    • Small size, economical
    • Delay time setting in starting and operation
    • Over current, phase failure protection
    • Definite time characteristics
    • Wide current setting range
    • Screw or Din-rail mounting
    Extended protective functions
    Extended protective functions
    Number of sensors 2CT
    Types (GMP-60T) Tunnel Type
    Functions Overcurrent
    Phase loss ■ Note1)
    Locked rotor
    Phase unbalance ·
    Phase reversed ·
+ Ratings
Ratings
Model GMP22 -2P GMP22 -2P(1a1b) GMP22 -3P/3PR GMP22 -2S GMP22 -3S/3SR GMP22 -2T GMP22 -3T/3TR
Ratings
Type Pin type Screw type Tunnel type
No. of CT 2CT 2CT 3CT 2CT 3CT 2CT 3CT
Protection Overcurrent
Phase failure  Note1)